Volume 26 Issue 04
Apr.  2014
Turn off MathJax
Article Contents
Liang Chuan, Xi Lulin, Zhou Lin, et al. Investigation and application of a portable 150 kV flash X-ray system[J]. High Power Laser and Particle Beams, 2014, 26: 045033. doi: 10.11884/HPLPB201426.045033
Citation: Liang Chuan, Xi Lulin, Zhou Lin, et al. Investigation and application of a portable 150 kV flash X-ray system[J]. High Power Laser and Particle Beams, 2014, 26: 045033. doi: 10.11884/HPLPB201426.045033

Investigation and application of a portable 150 kV flash X-ray system

doi: 10.11884/HPLPB201426.045033
  • Received Date: 2013-09-16
  • Rev Recd Date: 2013-11-28
  • Publish Date: 2014-03-28
  • A portable 150 kV flash X-ray system based on fast rise time mini-Marx generator principle was designed in coaxial structure. The experimental results of a 10-stage 150 kV Mini-Marx generator and flash X-ray tube were described. With a flash X-ray tube integrated directly into the Mini-Marx generator as a load, the formed flash X-ray system generated a dose of 7.710-6 C/kg at 25 cm away for flash X-radiography. It penetrated aluminium 60 mm in thickness with source size 1-3 mm.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2378) PDF downloads(273) Cited by()