Liang Chuan, Xi Lulin, Zhou Lin, et al. Investigation and application of a portable 150 kV flash X-ray system[J]. High Power Laser and Particle Beams, 2014, 26: 045033. doi: 10.11884/HPLPB201426.045033
Citation:
Liang Chuan, Xi Lulin, Zhou Lin, et al. Investigation and application of a portable 150 kV flash X-ray system[J]. High Power Laser and Particle Beams, 2014, 26: 045033. doi: 10.11884/HPLPB201426.045033
Liang Chuan, Xi Lulin, Zhou Lin, et al. Investigation and application of a portable 150 kV flash X-ray system[J]. High Power Laser and Particle Beams, 2014, 26: 045033. doi: 10.11884/HPLPB201426.045033
Citation:
Liang Chuan, Xi Lulin, Zhou Lin, et al. Investigation and application of a portable 150 kV flash X-ray system[J]. High Power Laser and Particle Beams, 2014, 26: 045033. doi: 10.11884/HPLPB201426.045033
A portable 150 kV flash X-ray system based on fast rise time mini-Marx generator principle was designed in coaxial structure. The experimental results of a 10-stage 150 kV Mini-Marx generator and flash X-ray tube were described. With a flash X-ray tube integrated directly into the Mini-Marx generator as a load, the formed flash X-ray system generated a dose of 7.710-6 C/kg at 25 cm away for flash X-radiography. It penetrated aluminium 60 mm in thickness with source size 1-3 mm.