Volume 26 Issue 04
Apr.  2014
Turn off MathJax
Article Contents
Huang Ziping, Jiang Wei, Ye Yi. Reset system for multi-pulse linear induction accelerator[J]. High Power Laser and Particle Beams, 2014, 26: 045101. doi: 10.11884/HPLPB201426.045101
Citation: Huang Ziping, Jiang Wei, Ye Yi. Reset system for multi-pulse linear induction accelerator[J]. High Power Laser and Particle Beams, 2014, 26: 045101. doi: 10.11884/HPLPB201426.045101

Reset system for multi-pulse linear induction accelerator

doi: 10.11884/HPLPB201426.045101
  • Received Date: 2013-09-04
  • Rev Recd Date: 2013-11-06
  • Publish Date: 2014-03-28
  • The triple-pulse linear induced accelerator (LIA) based on high voltage rectifier diodes needs an external reset system, for the diodes cut off the prepulse of the PFL charging which is used to reset the cavity cores of the single-pulse LIA. This paper describes the physics and circuit designs of the external reset unit, and introduces the layout of the whole reset system which includes other more units for charging, triggering and control. As a result, the system can reset the whole 92 cavities of the triple-pulse LIA steadily, quickly and fully.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (1385) PDF downloads(243) Cited by()