Volume 26 Issue 07
Jun.  2014
Turn off MathJax
Article Contents
Li Xiqin, Zhao Juan, Wu Hongguang, et al. Design of xenon flash lamp supply adopting integrally triggering and pre-ionization[J]. High Power Laser and Particle Beams, 2014, 26: 075004. doi: 10.11884/HPLPB201426.075004
Citation: Li Xiqin, Zhao Juan, Wu Hongguang, et al. Design of xenon flash lamp supply adopting integrally triggering and pre-ionization[J]. High Power Laser and Particle Beams, 2014, 26: 075004. doi: 10.11884/HPLPB201426.075004

Design of xenon flash lamp supply adopting integrally triggering and pre-ionization

doi: 10.11884/HPLPB201426.075004
  • Received Date: 2013-12-13
  • Rev Recd Date: 2014-03-15
  • Publish Date: 2014-06-10
  • A new xenon flash lamp triggering method is discussed based on trigger and pre-ionization integrally. The pre-ionized lamp is lighted by high voltage trigger circuit, and the current is kept by pulse forming network for 150 s. A trigger power supply is designed for the xenon lamp with a length of 160 mm, a diameter of 9 mm and a gap of 70 mm. The pre-ionized voltage amplitude is 300-900 V, pulse width is 150 s20 s, raising-time is less than 90 s, trigger delay time is less than 90 s, and jitter time is less than 2 s. Experimental results has testified the feasibility of the design theory and method.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2352) PDF downloads(628) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return