Accurate control technology of 24 modules in PTS

doi: 10.11884/HPLPB201830.170353
  • Received Date: 2017-09-05
  • Rev Recd Date: 2017-11-15
  • Publish Date: 2018-03-15
  • The accurate control technology for 24 modules of the Primary Test Stand (PTS) and the experimental results are given in this paper. The synchronicity of 24 lines pulsed current is controlled by 24 laser trigger switches. The current waveform can form through adjusting laser time easily. 24 laser trigger switches are triggered by 12 Q- switched Nd: YAG fourth harmonic 266 nm laser, i.e., two laser switches are triggered by one laser. The experimental results show that the jitter of the laser trigger system is less than 1.0 ns, the jitter of switch is less than 1.5 ns. The load current is 9.8 MA and the rising time of current is 75 ns under 65 kV charging voltage, when 24 modules are triggered synchronously. The adjusting range of rising time of current get to about 600 ns, 5.5 MA in PTS. The measured result of current waveform is consistent with the simulation result. The current waveform is repeatable for same load.
  • loading
  • [1]
    丰树平, 李洪涛, 谢卫平, 等. Z箍缩初级实验平台模块样机[J]. 强激光与粒子束, 2009, 21 (3): 463-467. http://www.hplpb.com.cn/article/id/3955

    Feng Shuping, Li Hongtao, Xie Weiping, et al. Development of prototype module of Z-pinch primary test stand. High Power Laser and Particle Beams, 2009, 21 (3): 463-467 http://www.hplpb.com.cn/article/id/3955
    [2]
    He An, Li Fengping, Deng Jianjun, et al. Primary investigation into the laser triggering multi-gap multi-channel gas switch in a single test module facility[J]. Plasma Sci Technol, 2006, 8 (5): 602-606.
    [3]
    Matzen M K, Sweeney M A, Adams R G. Pulsed-power-driven high energy density physics and inertial confinement fusion research[J]. Phys Plasmas, 2005, 12 : 055503. doi: 10.1063/1.1891746
    [4]
    Weinbrecht E A, Bloomquist D D, McDaniel D H, et al. Update of the Z Refurbishment project (ZR) at Sandia National Laboratories[C]//16th IEEE International Pulsed Power Conference. 2007: 975-978.
    [5]
    Rogowski S T, Bliss D E, Adams R G. A study of timing jitter improvements on Z with a new laser triggering system[C]//14th IEEE International Pulsed Power Conference. 2003: 1371-1374.
    [6]
    Weinbrecht E A, Bloomquist D D, McDaniel D H. Status of the Z Refurbishment Project (ZR) at Sandia National Laboratories[C]//15th IEEE International Pulsed Power Conference. 2005: 170-173.
    [7]
    Savage M, LeChien K, Stygar W. Overview and status of the upgraded z pulsed power driver[C]//IEEE International Power Modulator and High Voltage Conference. 2008: 93.
    [8]
    Li Hongtao, Xie Weiping, Feng Shuping, et al. Development of a high-reliability low-jitter 6 MV/300 kJ Marx generator[J]. Plasma Sources Sci Technol, 2008, 17 : 015001. doi: 10.1088/0963-0252/17/1/015001
    [9]
    Woodworth J R, Molina I, Nelson D. Green-laser-triggered water switching at 1. 6 MV[J]. IEEE Trans Dielectrics and Electrical Insulation, 2007, 14 (4): 951-957.