Volume 30 Issue 7
Jul.  2018
Turn off MathJax
Article Contents
Yang Hanwu, Xun Tao, Gao Jingming, et al. X-ray shielding estimations for rep-rate high power microwave accelerators[J]. High Power Laser and Particle Beams, 2018, 30: 073005. doi: 10.11884/HPLPB201830.170532
Citation: Yang Hanwu, Xun Tao, Gao Jingming, et al. X-ray shielding estimations for rep-rate high power microwave accelerators[J]. High Power Laser and Particle Beams, 2018, 30: 073005. doi: 10.11884/HPLPB201830.170532

X-ray shielding estimations for rep-rate high power microwave accelerators

doi: 10.11884/HPLPB201830.170532
More Information
  • Author Bio:

    Yang Hanwu(1974-), male, research professor, engaged in pulsed power and high power microwave technologies; yanghw@nudt.edu.cn

  • Received Date: 2017-12-30
  • Rev Recd Date: 2018-02-27
  • Publish Date: 2018-07-15
  • High power microwave research is moving into the high rep-rate regime and it will be common that an electron beam accelerator operates more than a million shots per year. As a result, accumulated bremsstrahlung X-ray produced by the electron beam collector is no longer negligible, and shielding is necessary for personnel safety. By using the BEAMnrc Monte-Carlo code, a typical collector for a ring beam usually used in HPM tube is simulated, which has beam voltage 1 MV, beam current 10 kA, pulse duration 100 ns and rep-rate 100 Hz. The results show the spectrum and spatial distribution of the X-ray generated at the collector. The attenuation factor of the X-ray is estimated from the simulation. The estimation of the skyshine radiation is also considered for the roof of the building.
  • loading
  • [1]
    Benford J, Swegle J A, Shamiloglu E. High power microwaves[M]. 2nd ed. New York: Taylor & Francis, 2007.
    [2]
    Zhang Jiande, Ge Xingjun, Zhang Jun et al. Research progress on Cherenkov and transit-time high-power microwave sources at NUDT[J]. Matter and Radiation at Extremes, 2016, 1(3): 163-173.
    [3]
    Mesyats G A, Korovin S D, Gunin A V, et al. Repetitively pulsed high-current accelerators with transformer charging of forming lines[J]. Laser and Particle Beams, 2003, 21: 197-209.
    [4]
    GB 18871-2002, Basic standards for protection against ionizing radiation and for the safety of radiation sources[S].
    [5]
    National Council on Radiation Protection and Measurements. Structural shielding design and evaluation for megavoltage X- and gamma-ray radiotherapy facilities[R]. NCRP Report No. 151, 2005.
    [6]
    Rogers D W O, Walters B, Kawrakow I. BEAMnrc User's Manual[R]. NRC Report PIRS-509A (rev L), 2013.
    [7]
    NIST SRD126. Tables of X-ray mass attenuation coefficients and mass energy absorption coefficients[DB/OL]. https://www.nist.gov/ pml/x-ray-mass-attenuation-coefficients.