Volume 31 Issue 1
Jan.  2019
Turn off MathJax
Article Contents
Li Qin, Liu Jun, Wang Yi, et al. Multi pulse X-ray dose measurement of Dragon-Ⅱ[J]. High Power Laser and Particle Beams, 2019, 31: 015101. doi: 10.11884/HPLPB201931.180234
Citation: Li Qin, Liu Jun, Wang Yi, et al. Multi pulse X-ray dose measurement of Dragon-Ⅱ[J]. High Power Laser and Particle Beams, 2019, 31: 015101. doi: 10.11884/HPLPB201931.180234

Multi pulse X-ray dose measurement of Dragon-Ⅱ

doi: 10.11884/HPLPB201931.180234
  • Received Date: 2018-09-10
  • Rev Recd Date: 2018-11-06
  • Publish Date: 2019-01-15
  • Dragon-Ⅱ is a linear induction accelerator, which can produce up to three bremsstrahlung X-ray pulses. Each X-ray pulse width is about 80 ns(FWHM), and time interval between pulses is about 500 ns. Each pulse X-ray dose is a critical parameter for Dragon-Ⅱ. Compton detector, combined with thermo luminescent dosemeter(TLD), was used to measure X-ray dose per pulse. MCNP program was used to design a Compton detector according to the characteristic of bremsstrahlung produced by Dragon-Ⅱ accelerator. Compton detector can measure multi-pulse X-ray signal and one pulse X-ray signal's integral is proportional to each pulse X-ray dose, and according to the total dose of three pulse X-ray obtained from TLD, each pulse X-ray dose can be obtained accurately.
  • loading
  • [1]
    石金水, 邓建军, 章林文, 等. 神龙二号加速器及其关键技术[J]. 强激光与粒子束, 2016, 28: 010201. doi: 10.11884/HPLPB201628.010201

    Shi Jinshui, Deng Jianjun, Zhang Linwen, et al. Dragon-Ⅱ and its key technology. High Power Laser and Particle Beams, 2016, 28: 010201 doi: 10.11884/HPLPB201628.010201
    [2]
    何国荣. 10 MeV LIA X光照射量测量[C]//10 MeV直线感应加速器会议文集. 1994.

    He Guorong. X-ray exposure measurement of 10MeV LIA//Proceedings of the Conference on 10 MeV Liner Induction Accelerator. 1994
    [3]
    苏毅. 康普顿二极管的研究[C]//核探测器核电子学1979年会议资料汇编. 1979.

    Su Yi. Study of Compton Diode//Proceedings of The Conference on Nuclear Detector and Nuclear Electronics. 1979
    [4]
    Carison G A, Sanford T W L. A solid dielectric Compton diode for measuring short radiation pulse widths[J]. Rev Sci Instrum, 1990, 61(11): 3447-3451. doi: 10.1063/1.1141600
    [5]
    欧阳晓平, 张忠兵, 王群书, 等. 用于脉冲n/γ混合场γ强度测量的ICI探测器[J]. 高能物理与核物理, 2006, 30(3): 228-231. https://www.cnki.com.cn/Article/CJFDTOTAL-KNWL200603010.htm

    Ouyang Xiaoping, Zhang Zhongbing, Wang Qunshu, et al. ICI detector for measuring gamma-ray fluxes in mixed gamma-neutron fields. High Energy Physics and Nuclear Physics, 2006, 30(3): 228-231 https://www.cnki.com.cn/Article/CJFDTOTAL-KNWL200603010.htm
    [6]
    张忠兵, 欧阳晓平, 王伟. ICI探测器单位γ灵敏度研究[J]. 核电子学与探测技术, 2007, 27(1): 5-7. doi: 10.3969/j.issn.0258-0934.2007.01.002

    Zhang Zhongbing, Ouyang Xiaoping, Wang Wei. The sensitivity response of ICI detector for γ-ray. Nuclear Electronics & Detection Technology, 2007, 27(1): 5-7 doi: 10.3969/j.issn.0258-0934.2007.01.002
    [7]
    Fewell T R. Compton diodes: Theory and development for radiation detectors[R]. SC-DR-720118, 1972.
    [8]
    胡孟春, 陈发新, 李忠宝, 等. 能量响应相对平坦的康普顿探测器[J]. 核电子学与探测技术, 2005, 25(6): 668-670. doi: 10.3969/j.issn.0258-0934.2005.06.025

    Hu Mengchun, Chen Faxin, Li Zhongbao, et al. The Compton detector with relative steady-state energy response. Nuclear Electronics & Detection Technology, 2005, 25(6): 668-670 doi: 10.3969/j.issn.0258-0934.2005.06.025
    [9]
    Hsu H H, Lee H. Monte Carlo calculations of the vacuum Compton detector sensitivities[R]. LA-UR-89-2375, 1989.
    [10]
    李勤, 刘军. 康普顿探测器优化设计[J]. 强激光与粒子束, 2010, 22(3): 635-638. http://www.hplpb.com.cn/article/id/4205

    Li Qin, Liu Jun. Optimization design of Compton detector. High Power Laser and Particle Beams, 2010, 22(3): 635-638 http://www.hplpb.com.cn/article/id/4205
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(5)  / Tables(3)

    Article views (1009) PDF downloads(117) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return