  • Received Date: 2018-10-19
  • Rev Recd Date: 2019-01-18
  • Publish Date: 2019-02-15
  • In the RF system of the accelerator, when the reflected power back to the klystron in the current RF pulse exceeds certain threshold, the system should send out an alarm signal before the next RF pulse arrives, and then cut off the trigger signal. By this way, the klystron ceramic window can be protected by reducing the damage caused by the high-power RF reflection; the online lifetime of the klystron can be prolonged. Three cost-effective and easy-to-implement solutions have been introduced: the mask alarm scheme by using the PicoScope virtual oscilloscope, the chip-made reflective protection plug-in based on the RF detection and alarm output functions, and the upgrade of the original RF power meter. The "3+1" reflection protection response time test method was innovatively proposed, it was used to thoroughly test the above three schemes. Finally, better results were obtained by using the latter two schemes. After comprehensive consideration, the upgraded RF power meter was used in the final implementation plan. At present, the upgraded RF power meter has been operating online stably and reliably for more than one year.
  • loading
  • [1]
    Pei Guoxi, Sun Yaolin, Chi Yunlong, et al. Progress of the injector linac upgrade for the BEPCⅡ project[J]. High Energy Physics & Nuclear Physics, 2004, 28(11): 1214-1218. https://www.researchgate.net/publication/296726069_Progress_of_the_injector_linac_upgrade_for_the_BEPC_II_Project
    [2]
    赵风利, 侯汨, 赵延坪, 等. BEPCⅡ直线加速器微波系统[J]. 高能物理与核物理, 2006, 30(2): 78-83. https://www.cnki.com.cn/Article/CJFDTOTAL-KNWL200602014.htm

    Zhao Fengli, Hou Mi, Zhao Yanping, et al. Microwave system for BEPCⅡ-linac. High Energy Physics & Nuclear Physics, 2006, 30(2): 78-83 https://www.cnki.com.cn/Article/CJFDTOTAL-KNWL200602014.htm
    [3]
    Hou Mi, Zhou Zusheng. RF power test and conditioning of the new accelerating structure for the BEPCⅡ-linac[J]. High Energy Physics & Nuclear Physics, 2005, 29(1): 93-97. https://oversea.cnki.net/kcms/detail/detail.aspx?filename=KNWL200501019&dbcode=CJFD&dbname=CJFD2005&v=
    [4]
    Rees D E, Bradley J, Cummings K, et al. The SNS linac high power RF system design, status, and results[C]//Proc of Particle Accelerator Conference. 2003.
    [5]
    韩大威, 赵风利. BEPCⅡ直线加速器微波功率监测系统[C]//全国加速器微波、高频技术研讨会. 2005.

    Han Dawei, Zhao Fengli. BEPCⅡ Linac Microwave Power Monitoring System//National Accelerator Microwave, RF Technology Seminar. 2005
    [6]
    吕海艇, 邵贝贝, 郑曙昕, 等. CPHS速调管驻波比保护系统[J]. 核电子学与探测技术, 2014, 34(4): 425-428. https://www.cnki.com.cn/Article/CJFDTOTAL-HERE201404002.htm

    Lü Haiting, Shao Beibei, Zhen Shuxin, et al. Standing wave ratio protection system for klystron on CPHS. Nuclear Electronics & Detection Technology, 2014, 34(4): 425-428 https://www.cnki.com.cn/Article/CJFDTOTAL-HERE201404002.htm
    [7]
    王修龙, 粟国萍, 张梅芳, 等. 宽脉冲高功率速调管快速保护系统[J]. 中国核科技报告, 1995(S2): 387-395. https://www.cnki.com.cn/Article/CJFDTOTAL-ZHBG199500031.htm

    Wang Xiulong, Su Guoping, Zhang Meifang, et al. A quick-response protective system for high power klystron with long pulse. China Nuclear Science and Technology Report, 1995(S2): 387-395 https://www.cnki.com.cn/Article/CJFDTOTAL-ZHBG199500031.htm
    [8]
    Hara M, Ego H, Kawashima Y, et al. RF stations of the Spring-8 storage ring[C]//Proc of Particle Accelerator Conference. 1998.
    [9]
    Wang Fang, Wang Guangwei, Lu Jianfa, et al. Low level control RF system for SSRF[C]//Proc of APAC. 2001.
    [10]
    PicoScope3000D系列混合信号USB3.0示波器[J]. 电子产品世界, 2014, 21(10): 72.

    PicoScope 3000D series mixed signal USB3.0 oscilloscope. Electronic Engineering & Product World, 2014, 21(10): 72
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(6)  / Tables(1)

    Article views (1612) PDF downloads(100) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return