Volume 36 Issue 5
Apr.  2024
Turn off MathJax
Article Contents
Zhang Xinjun, Luo Weixi, Hu Yixiang, et al. A design of B-dot calibration simulator for azimuthal transmission line[J]. High Power Laser and Particle Beams, 2024, 36: 055002. doi: 10.11884/HPLPB202436.230341
Citation: Zhang Xinjun, Luo Weixi, Hu Yixiang, et al. A design of B-dot calibration simulator for azimuthal transmission line[J]. High Power Laser and Particle Beams, 2024, 36: 055002. doi: 10.11884/HPLPB202436.230341

A design of B-dot calibration simulator for azimuthal transmission line

doi: 10.11884/HPLPB202436.230341
  • Received Date: 2023-10-06
  • Accepted Date: 2024-03-15
  • Rev Recd Date: 2024-03-15
  • Available Online: 2024-03-25
  • Publish Date: 2024-04-28
  • An off-line calibration platform is designed based on the requirement of off-line calibration of induction cavity azimuthal transmission line current probe. The analog device is a flat-plate transmission line structure, which has lower distortion than on-line calibration. The source of cross-platform calibration error is analyzed, and the measures to reduce the error are put forward. The analysis shows that the installation eccentricity and probe longitudinal installation depth are the biggest sources of cross-platform calibration error, which need to be paid attention to in engineering design. An off-line calibration platform is established and the error analysis is carried out. As a result, 3.3% cross-platform calibration error is obtained.
  • loading
  • [1]
    Smith I D. Induction voltage adders and the induction accelerator family[J]. Physical Review Special Topics—Accelerators and Beams, 2004, 7: 064801. doi: 10.1103/PhysRevSTAB.7.064801
    [2]
    丛培天, 张国伟, 吴撼宇, 等. 3MV感应电压叠加器的磁感应腔研制[J]. 强激光与粒子束, 2011, 23(2):563-568 doi: 10.3788/HPLPB20112302.0563

    Cong Peitian, Zhang Guowei, Wu Hanyu, et al. Design of inductive cavity for 3 MV induction voltage adder[J]. High Power Laser and Particle Beams, 2011, 23(2): 563-568 doi: 10.3788/HPLPB20112302.0563
    [3]
    郭帆. 感应电压叠加器中感应腔系统研制[D]. 合肥: 中国科学技术大学, 2019

    Guo Fan. Design and performance of the induction cavities system for an induction voltage adder[D]. Hefei: University of Science and Technology of China, 2019
    [4]
    Ramirez J J, Prestwich K R, Burgess E L, et al. The Hermes-III program[C]//Proceedings of Institute of Electrical and Electronic Engineers Pulsed Power Conference. 1987: 294-299.
    [5]
    Johnson D L, Ramirez J J, Huddle C W, et al. Hermes-III prototype cavity tests[C]//Proceedings of Institute of Electrical and Electronic Engineers Pulsed Power Conference. 1987: 482-485.
    [6]
    魏浩, 孙凤举, 邱爱慈, 等. 单/双路馈入磁绝缘感应电压叠加器感应腔角向传输线的优化[J]. 高电压技术, 2014, 40(7):2232-2237

    Wei Hao, Sun Fengju, Qiu Aici, et al. Optimization of azimuthal transmission lines for magnetically insulated induction voltage adders driven by single or double pulses[J]. High Voltage Engineering, 2014, 40(7): 2232-2237
    [7]
    来定国, 张永民, 谢霖燊, 等. 快脉冲高电压大电流测量探头标定方法[J]. 强激光与粒子束, 2010, 22(10):2469-2472 doi: 10.3788/HPLPB20102210.2469

    Lai Dingguo, Zhang Yongmin, Xie Linshen, et al. Calibrating method of high voltage and current probe for fast pulse measurements[J]. High Power Laser and Particle Beams, 2010, 22(10): 2469-2472 doi: 10.3788/HPLPB20102210.2469
    [8]
    姚伟博, 张永民, 来定国, 等. 用于诊断纳秒脉冲电流的微分环现场标定技术[J]. 强激光与粒子束, 2012, 24(2):501-504 doi: 10.3788/HPLPB20122402.0501

    Yao Weibo, Zhang Yongmin, Lai Dingguo, et al. Field calibration method for nanosecond pulse differential ring[J]. High Power Laser and Particle Beams, 2012, 24(2): 501-504 doi: 10.3788/HPLPB20122402.0501
    [9]
    郭宁, 王亮平, 韩娟娟, 等. 测量1 MA/100 ns脉冲大电流的微分环[J]. 强激光与粒子束, 2012, 24(3):519-523 doi: 10.3788/HPLPB20122403.0519

    Guo Ning, Wang Liangping, Han Juanjuan, et al. Differential loop for measuring 1 MA/100 ns pulsed high current[J]. High Power Laser and Particle Beams, 2012, 24(3): 519-523 doi: 10.3788/HPLPB20122403.0519
    [10]
    卫兵, 卿燕玲, 丰树平, 等. 4层圆盘锥形磁绝缘传输线的电流测量[J]. 强激光与粒子束, 2014, 26:085002 doi: 10.3788/HPLPB20142608.85002

    Wei Bing, Qing Yanling, Feng Shuping, et al. Current measurement for four-level magnetically-insulated transmission line[J]. High Power Laser and Particle Beams, 2014, 26: 085002 doi: 10.3788/HPLPB20142608.85002
    [11]
    呼义翔, 韩娟娟, 郭宁, 等. 磁绝缘传输线电流测量差模式B-dot探头[J]. 强激光与粒子束, 2012, 24(10):2511-2515 doi: 10.3788/HPLPB20122410.2511

    Hu Yixiang, Han Juanjuan, Guo Ning, et al. Differential B-dot monitor used for current measure of magnetically insulated transmission lines[J]. High Power Laser and Particle Beams, 2012, 24(10): 2511-2515 doi: 10.3788/HPLPB20122410.2511
    [12]
    卫兵, 但加坤, 付佳斌, 等. 空腔中B-dot的低频响应特性[J]. 强激光与粒子束, 2016, 28:015026 doi: 10.11884/HPLPB201628.015026

    Wei Bing, Dan Jiakun, Fu Jiabin, et al. Low frequency response characteristics of B-dot monitor in cavity[J]. High Power Laser and Particle Beams, 2016, 28: 015026 doi: 10.11884/HPLPB201628.015026
    [13]
    卫兵, 康军军, 王杰, 等. 空腔中B-dot低频特性的硬件补偿[J]. 强激光与粒子束, 2020, 32:025021 doi: 10.11884/HPLPB202032.190309

    Wei Bing, Kang Junjun, Wang Jie, et al. Hardware compensation of B-dot low frequency characteristics in cavity[J]. High Power Laser and Particle Beams, 2020, 32: 025021 doi: 10.11884/HPLPB202032.190309
    [14]
    GB/T 1804-2000, 一般公差 未注公差的线性和角度尺寸的公差[S]

    GB/T 1804-2000, General tolerances- Tolerances for linear and angular dimensions without individual tolerance indications[S]
    [15]
    钱绍圣. 测量不确定度: 实验数据的处理与表示[M]. 北京: 清华大学出版社, 2002

    Qian Shaosheng. Measurement uncertainty: processing and representation of experimental data[M]. Beijing: Tsinghua University Press, 2002
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(8)  / Tables(2)

    Article views (32) PDF downloads(2) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return