Volume 24 Issue 03
Jun.  2016
Turn off MathJax
Article Contents
Huang Lei, Li Xiqin, Feng Zongming, et al. Design of trigger device for repetitive pulsed power system[J]. High Power Laser and Particle Beams, 2012, 24: 681-684. doi: 10.3788/HPLPB20122403.0681
Citation: Huang Lei, Li Xiqin, Feng Zongming, et al. Design of trigger device for repetitive pulsed power system[J]. High Power Laser and Particle Beams, 2012, 24: 681-684. doi: 10.3788/HPLPB20122403.0681

Design of trigger device for repetitive pulsed power system

doi: 10.3788/HPLPB20122403.0681
  • Received Date: 2011-11-07
  • Rev Recd Date: 2011-12-13
  • Publish Date: 2012-03-05
  • According to the trigger method of high-power switch device hydrogen thyratron used in the repetitive pulsed power system, a trigger device was designed for hydrogen thyratron VE4147, which can output -150 V DC bias, and pulses with voltage 2 000 V, current 10 A, width 800 ns and repetition-rate up to 10 kHz. The design takes into account interference protection, low power consumption, thermal management and so on, to make sure that such trigger device can work uninterruptedly at the repetition-rate of 10 kHz. So far the trigger device has been used in sorts of repetitive pulsed power systems, such as 100 kV/2 kHz high-voltage pulsed power supply, 70 kV/10 kHz hydrogen thyratron aging platform, and 150 kV/1 kHz corona plasma generator of adjustable pulse width.
  • loading