Volume 24 Issue 10
Sep.  2012
Turn off MathJax
Article Contents
Xia Minghe, Ji Ce, Wang Yujuan, et al. Pulse output switch of Primary Test Stand[J]. High Power Laser and Particle Beams, 2012, 24: 2516-2520. doi: 10.3788/HPLPB20122410.2516
Citation: Xia Minghe, Ji Ce, Wang Yujuan, et al. Pulse output switch of Primary Test Stand[J]. High Power Laser and Particle Beams, 2012, 24: 2516-2520. doi: 10.3788/HPLPB20122410.2516

Pulse output switch of Primary Test Stand

doi: 10.3788/HPLPB20122410.2516
  • Received Date: 2012-03-01
  • Rev Recd Date: 2012-04-09
  • Publish Date: 2012-10-15
  • The self-breakdown water switch with coaxial-triplate configuration is used for the pulse output switch of the pulse forming section in Primary Test Stand (PTS). The research contains two stages, the first is the 1.5 MV coaxial water switch experiment on FLASH-Ⅱand the second is the experiment of 4 MV coaxial-triplate multi-channel water switch on the prototype module of PTS. Results show that the output current is 500 kA with 100 ns rise time at 3.5 MV self-breakdown voltage, the total switch inductance is 65 nH, and the jitter of charging time is 1.3 ns.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (1651) PDF downloads(335) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return