In this paper three wavelengths 266nm,289nm,308nm are used for experimental studies of simulation and measurements. Results of simulation show that the effects are larger for twowavelength DIAL but less for threewavelength dual DIAL, if spatial inhomogeneity of aerosol and gradient of backscatter ratio are larger.