The performance process of indirectly feeding, helical magnetic flux compssion generator are studied with five-section model. The dependences of the system magnetic flux multiplication and energy multiplication ratios on construction parameters are analyzed. The effects of tapering angle, misalignment between armature and coil are also discussed.