Volume 08 Issue 02
May  1996
Turn off MathJax
Article Contents

  • Publish Date: 1996-05-15
  • This paper presents our research work on the pulsed taut – wire measurement of the magnetic alignment of the high current induction – cell. A fine taut – wire carrying a pulse current was put in the solenoid magnet, and observing the Lorentz force on the wire. If the magnetic axis is an offset or a tilt of the mechanical axis of the solenoid, the wave pattern produced by these errors are different from that produced by the correct one. In our experiments we changed the current pulse amplitude from 0.3A to 3.8A and its width from 300m s to 1.5ms, the length of the solenoid is 40cm, the centering error of the wire is ± 0.05mm. The tilt, the offset and their direction can be distinguished from the waveform. The experimental sensitivity of tilt we estimated is 1mard.Lastly to differentiate
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2117) PDF downloads(572) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return