Volume 14 Issue 02
Apr.  2002
Turn off MathJax
Article Contents
zhao wei-li, sang feng-ting, duo li-ping, et al. Measurements of the species concentration in flow field with the technique of spontaneous Raman imaging (II)[J]. High Power Laser and Particle Beams, 2002, 14.
Citation: zhao wei-li, sang feng-ting, duo li-ping, et al. Measurements of the species concentration in flow field with the technique of spontaneous Raman imaging (II)[J]. High Power Laser and Particle Beams, 2002, 14.

Measurements of the species concentration in flow field with the technique of spontaneous Raman imaging (II)

  • Publish Date: 2002-04-15
  • A spontaneous Raman imaging system which can monitor the concentrations of major species in flow field in real time has been described. The results of the low pressure O2 are presented and the lowest pressure we measure is 133Pa. This technique can be calibrated in real time by an introduction of a known amount of N2. The error is less than 8%. The measurement precision of O2(a1Δ) concentration will be improved largely when this technique is applied to monitor chemical oxygen-iodine laser singlet oxygen generator performance.