Volume 19 Issue 05
May  2007
Turn off MathJax
Article Contents
wei bing, gu yuan-chao, zhou rong-guo, et al. Design, calibration and measurement of D-dot monitor for Yang accelerator water transmission line[J]. High Power Laser and Particle Beams, 2007, 19.
Citation: wei bing, gu yuan-chao, zhou rong-guo, et al. Design, calibration and measurement of D-dot monitor for Yang accelerator water transmission line[J]. High Power Laser and Particle Beams, 2007, 19.

Design, calibration and measurement of D-dot monitor for Yang accelerator water transmission line

  • Publish Date: 2007-05-15
  • A D-dot monitor was designed to measure the voltage of Yang accelerator water transmission line. A signal proportional to the time derivative of the voltage was given with capacitor from high voltage electrode to the probe and the voltage was given with the RC integrator. The parameters (inductance and capacitance) were estimated using the transient analysis of OrCAD/Pspice and the amplitude-frequency response of the monitor was analyzed. The result of measurement can be explained using the analysis. The monitor was calibrated in-situ with resistive divider while accelerator was short-circuit at lower Marx-bank charge voltages. The experimental result indicates that the designed D-dot monitor is satisfactory to the measurement requirement.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2117) PDF downloads(513) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return