Volume 20 Issue 02
Feb.  2008
Turn off MathJax
Article Contents
li zhi-qiang, zhong hui-huang, fan yu-wei, et al. Experimental research of S-band tapered magnetically insulated transmission line oscillator at long-pulse operation[J]. High Power Laser and Particle Beams, 2008, 20.
Citation: li zhi-qiang, zhong hui-huang, fan yu-wei, et al. Experimental research of S-band tapered magnetically insulated transmission line oscillator at long-pulse operation[J]. High Power Laser and Particle Beams, 2008, 20.

Experimental research of S-band tapered magnetically insulated transmission line oscillator at long-pulse operation

  • Publish Date: 2008-02-15
  • An S-band tapered magnetically insulated transmission line oscillator with slowly tapered vanes and sharply tapered vanes has been studied at long-pulse operation. Under the diode voltage of 350 kV, the diode current of 25 kA and the pulse duration of 128 ns, the output microwave with the power of 500 MW and the pulse duration of 90 ns has been obtained in the experiments. Further analysis showed that the poor microwave shape attributed to the poor diode voltage waveform and better diode voltage waveform was crucial to achieving a longer microwave pulse. In addition, two kinds of load structure were used to collect the e-beams. The experimental results indicat that using the graphite load could get the better performance than the stainless steel load.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2070) PDF downloads(483) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return