Volume 20 Issue 03
Mar.  2008
Turn off MathJax
Article Contents
ma liang, zhou hui, cheng yin-hui, et al. Research on HEMP response of ground laid cables[J]. High Power Laser and Particle Beams, 2008, 20.
Citation: ma liang, zhou hui, cheng yin-hui, et al. Research on HEMP response of ground laid cables[J]. High Power Laser and Particle Beams, 2008, 20.

Research on HEMP response of ground laid cables

  • Publish Date: 2008-03-15
  • The characteristics of current induced by HEMP on cable’s shielding layer has been researched by multiresolution analysis in time domain. There are several factors, including height from cable to ground, length of cable and direction of incident HEMP, having effect on the current. The relationship between the induced current and the factors is analyzed. The analysis shows that, the higher the height from cable to ground is, the bigger the amplitude of the induced current is. It also indicates that, the amplitude, rising time and FWHM of the induced current are increasing while the length of the cable is getting longer until they all reach their own maxima. The distribution of the induced current along the cable with normal HEMP incidence is different from that with oblique incidence, and
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2008) PDF downloads(483) Cited by()