A symmetrical pulsed high magnetic field generator is equipped to generate high magnetic field of 18 T, and its field period is about 10 μs. The energy storage of the equipment depends on the pulsed capacitor. Its transmission system consists of a flat transmission line, cables and gas switches. The load is a single circular winding. For the two symmetrical loads to work at the same moment, a synchro trigger system is made, whose time dispersion is about 20 ns. When the working voltage of the generator and the synchro trigger system come up to 28 kV and 49 kV, respectively, and the air pressure of the gas switch reaches about 80 kPa, the highest intensity of magnetization in the center of the winding is 18 T.