A new trigatron with a discal trigger electrode has been tested on its trigger characteristics. And the effects of different polarity combinations, trigger pulse amplitudes and trigger resistances on trigger characteristics of the trigatron have been derived. Then the breakdown mechanism was introduced to explain the results. It is found that the optimum polarity combination is heteropolarity and the best scope of the ratio between trigger voltage and self-breakdown voltage is 30%~50%. The appropriate trigger resistance is 50~100 Ω to achieve large current considering the safety operation of the trigatron.