yu haijun, cheng jian, zhu jun, et al. Measurement of backstreaming ions produced at bremsstrahlung converter target of Dragon-Ⅰlinear induction accelerator[J]. High Power Laser and Particle Beams, 2010, 22.
Citation:
yu haijun, cheng jian, zhu jun, et al. Measurement of backstreaming ions produced at bremsstrahlung converter target of Dragon-Ⅰlinear induction accelerator[J]. High Power Laser and Particle Beams, 2010, 22.
yu haijun, cheng jian, zhu jun, et al. Measurement of backstreaming ions produced at bremsstrahlung converter target of Dragon-Ⅰlinear induction accelerator[J]. High Power Laser and Particle Beams, 2010, 22.
Citation:
yu haijun, cheng jian, zhu jun, et al. Measurement of backstreaming ions produced at bremsstrahlung converter target of Dragon-Ⅰlinear induction accelerator[J]. High Power Laser and Particle Beams, 2010, 22.
The Dragon-Ⅰlinear induction accelerator(LIA) uses mm level diameter pulsed electron beam to strike the bremsstrahlung converter target to generate X-ray, which generates the backstreaming ions as well. Four Faraday cups are combined to collect backstreaming ions produced at the bremsstrahlung converter target of the Dragon-ⅠLIA. Experiment and calculation results show that the backstreaming positive ions density and velocity are about 1021/m3 and 2~3 km/s,respectively.The calculated results show that the intensity of the backstreaming positive ion beam is only 0.27% of that of the targeting electron beam, thus the backstreaming ions would not affect the focus of the electron beam.