Volume 23 Issue 04
Apr.  2011
Turn off MathJax
Article Contents
shi aimin, wang xianwu, wen lianghua, et al. Directional coupler-based measurement of high-frequency power[J]. High Power Laser and Particle Beams, 2011, 23.
Citation: shi aimin, wang xianwu, wen lianghua, et al. Directional coupler-based measurement of high-frequency power[J]. High Power Laser and Particle Beams, 2011, 23.

Directional coupler-based measurement of high-frequency power

  • Publish Date: 2011-04-14
  • In order to realize accurate power measurement and effective protection of the transmitter, the principle of directional coupler, and the method of parameter calibration and power measurement applied to the RF transmitter system are described. According to the measurements, the method has the advantages of simple installation, high precision, and dynamic calibration. After parameter calibration, the output power and standing wave ratio are measured online by installing a coaxial directional coupler between the RF power source and the resonant cavity. The measurements are then sent to the system of control, protection and monitoring to complete high-power measurement and protection of devices.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2085) PDF downloads(621) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return