| Citation: | Zhou Jianxin, Kang Wen, Li Shuai, et al. Research on measurement of integral field uniformity of CSNS corrector magnets[J]. High Power Laser and Particle Beams, 2019, 31: 115105. doi: 10.11884/HPLPB201931.190028 |
| [1] |
DiMarco J, Harding D J, Kashikhin V, et al. Test results of the AC field measurements of FERMILAB booster corrector magnets[C]//Proceedings of EPAC08. 2008: 2347-2349.
|
| [2] |
Harding D J, DiMarco J, Drennan C C, et al. Design and fabrication of a multi-element corrector magnet for the FERMILAB booster synchrotron[C]//Proceedings of PAC07. 2007: 452-454.
|
| [3] |
Parker B, Anerella M, Escallier J, et al. The SuperKEKB interaction region corrector magnets[C]//Proceedings of IPAC16. 2016: 1193-1195.
|
| [4] |
DiMarco J. Fundamentals of magnetic measurements with rotating coils: A tutorial[R]//19th International magnet Measurement Workshop. 2015.
|
| [5] |
Arpaia P, Buzio M, De Oliveira R, et al. A high-precision miniaturized rotating coil transducer for magnetic measurements[J]. Sensor and Actuators A: Physical, 2018, 274: 37-49.
|
| [6] |
Fu S N, Chen H S, Chen Y W, et al. Status of CSNS project[C]//Proceedings of IPAC13. 2013: 3995-3999.
|
| [7] |
Wang Sheng, An Yuwen, Fang Shouxian, et al. An overview of design for CSNS/RCS and beam transport[J]. Sci China-Phys Mech Astron, 2011, 54: 239-244. doi: 10.1007/s11433-011-4564-x
|
| [8] |
Inner Technique Note[Z]. CSNS-ACAP-TC-11-06, CSNS-ACAP-TC-12-13, CSNS-ACMT-TC-14-04.
|
| [9] |
Tanabe J. Iron dominated electromagnets design, fabrication, assembly and measurements[R]. SLAC-R-754, 2005.
|
| [10] |
Jain A K. Measurements of field quality using harmonic coils[R/OL]. https://www.bnl.gov/magnets/staff/Gupta/scmagcourse/Harmoniccoil-slides.PDF, 2001.
|
| [11] |
Zhao Jijiu, Yin Zhaosheng. Particle accelerator technology[M]. Beijing: Higher Education Press, 2006.
|
| [12] |
Zhou Jianxin, Kang Wen, Li Shuai, et al. Development of rotating coil measurement system for China Spallation Neutron Source[J]. High Power Laser and Particle Beams, 2018, 30: 105101.
|
| [13] |
Zhou J X, Li L, Yin Baogui, et al. A harmonic coil measurement system based on a dynamic signal acquisition device[J]. Nuclear Instruments and Methods in Physics Research A, 2010, 624: 549-553. doi: 10.1016/j.nima.2010.10.009
|
| [14] |
Zhou Jianxin, Kang Wen, Yin Baogui, et al. The development of magnetic field measurement system for drift-tube linac quadrupole[J]. Nuclear Instruments and Methods in Physics Research A, 2015, 786: 142-146. doi: 10.1016/j.nima.2015.03.050
|
| [15] |
Zhou Jianxin, Kang Wen, Li Shuai, et al. AC magnetic field measurement using a small flip coil system for rapid cycling AC magnets at the China Spallation Neutron Source (CSNS)[J]. Nuclear Instruments and Methods in Physics Research A, 2018, 880: 80-86. doi: 10.1016/j.nima.2017.10.040
|