Citation: | Zheng Zheng, Xia Chunmei, Mei Qiliang, et al. Preliminary validation and application of shutdown dose rate calculation method based on cell-in-mesh[J]. High Power Laser and Particle Beams. doi: 10.11884/HPLPB202537.250009 |
[1] |
Valenza D, Iida H, Plenteda R, et al. Proposal of shutdown dose estimation method by Monte Carlo code[J]. Fusion Engineering and Design, 2001, 55(4): 411-418. doi: 10.1016/S0920-3796(01)00188-0
|
[2] |
陈义学, 吴宜灿, Fischer U. 核聚变装置停机剂量率分析计算的严格两步(R2S)法[J]. 核技术, 2003, 26(10): 763-766
Chen Yixue, Wu Yican, Fischer U. The rigorous 2-step calculation of shutdown dose rates for nuclear fusion devices[J]. Nuclear Techniques, 2003, 26(10): 763-766
|
[3] |
Kim J H, Woo M H, Shin C H, et al. A shutdown dose rates analysis of the Korean fusion demonstration reactor using MCNP5 mesh-based R2S approach[J]. Fusion Engineering and Design, 2021, 167: 112321. doi: 10.1016/j.fusengdes.2021.112321
|
[4] |
Sauvan P, Juárez R, Pedroche G, et al. D1SUNED system for the determination of decay photon related quantities[J]. Fusion Engineering and Design, 2020, 151: 111399. doi: 10.1016/j.fusengdes.2019.111399
|
[5] |
Serikov A G, Sheludjakov S V. Method for three-dimensional activation analysis of fusion reactor materials[J]. Plasma Devices and Operations, 2001, 9: 237-272. doi: 10.1080/10519990108229760
|
[6] |
郑剑, 李斌, 邹俊, 等. 基于网格计数的停机剂量率计算方法研究[J]. 核科学与工程, 2016, 36(6): 784-789
Zheng Jian, Li Bin, Zou Jun, et al. Rigorous two-step shutdown dose rate calculation method based on mesh tally[J]. Nuclear Science and Engineering, 2016, 36(6): 784-789
|
[7] |
Sauvan P, Catalan J P, Ogando F, et al. Development of the R2SUNED code system for shutdown dose rate calculations[J]. IEEE Transactions on Nuclear Science, 2016, 63(1): 375-384. doi: 10.1109/TNS.2015.2507138
|
[8] |
Wilson S C, Mosher S W, Royston K E, et al. Validation of the MS-CADIS method for full-scale shutdown dose rate analysis[J]. Fusion Science and Technology, 2018, 74(4): 288-302. doi: 10.1080/15361055.2018.1483687
|
[9] |
Ibrahim A M, Peplow D E, Grove R E, et al. The multi-step CADIS method for shutdown dose rate calculations and uncertainty propagation[J]. Nuclear Technology, 2015, 192(3): 286-298. doi: 10.13182/NT15-1
|
[10] |
Jaboulay J C, Brun E, Hugot F X, et al. Rigorous-two-steps scheme of TRIPOLI-4 Monte Carlo code validation for shutdown dose rate calculation[J]. EPJ Web of Conferences, 2017, 153: 02008. doi: 10.1051/epjconf/201715302008
|
[11] |
Eade T, Colling B, Naish J, et al. Shutdown dose rate benchmarking using modern particle transport codes[J]. Nuclear Fusion, 2020, 60: 056024. doi: 10.1088/1741-4326/ab8181
|
[12] |
Eade T, Stonell D, Turner A. MCR2S Unstructured mesh capabilities for use in shutdown dose rate analysis[J]. Fusion Engineering and Design, 2015, 100: 321-333. doi: 10.1016/j.fusengdes.2015.06.189
|
[13] |
李雷鸣, 江书益, 陈珍平, 等. 核反应堆结构材料网格精细活化分析研究[J]. 核技术, 2022, 45: 080601 doi: 10.11889/j.0253-3219.2022.hjs.45.080601
Li Leiming, Jiang Shuyi, Chen Zhenping, et al. Mesh-based activation analysis for structural materials in nuclear reactor[J]. Nuclear Techniques, 2022, 45: 080601 doi: 10.11889/j.0253-3219.2022.hjs.45.080601
|
[14] |
张显, 刘仕倡, 卢棚, 等. 基于严格两步法的停堆剂量率计算程序的基准分析[J]. 辐射防护, 2023, 43(s1): 20-24
Zhang Xian, Liu Shichang, Lu Peng, et al. Benchmark analysis of shutdown dose rate calculation program based on R2S method[J]. Radiation Protection, 2023, 43(s1): 20-24
|
[15] |
Deng L, Ye T, Li G, et al. 3-D Monte Carlo neutron-photon transport code JMCT and its algorithms[C]//Proceedings of International Conference on Physics of Reactors. 2014.
|
[16] |
Gauld I C. ORIGEN-S: SCALE system module to calculate fuel depletion, actinide transmutation, fission product buildup and decay, and associated radiation source terms[R]. ORNL/TM-2005/39, 2009.
|
[17] |
American Nuclear Society. American national standard neutron and gamma-ray flux-to-dose-rate factors[R]. LaGrange Park, Illinois: American Nuclear Society, 1977.
|
[18] |
Sterbentz J W, Werner J E, McKellar M G, et al. Special purpose nuclear reactor (5 MW) for reliable power at remote sites assessment report[R]. Idaho Falls: Idaho National Laboratory, 2017.
|