Explosives detection in mobile phones based on dual-energy computed laminography

doi: 10.11884/HPLPB202638.250358
  • Received Date: 2025-10-20
  • Accepted Date: 2026-01-21
  • Rev Recd Date: 2026-02-06
  • Available Online: 2026-03-10
  • Background
    In the 2024 series of Beirut explosions in Lebanon, terrorists hid trace high-explosive materials in electronic products to carry out attacks, exposing the shortcomings of the current detection system. Existing trace detection technologies cannot penetrate the casings of electronic products, while in bulk detection technologies, CT has limitations in imaging plate-like components such as mobile phones, and conventional X-ray security inspectors lack sufficient resolution. Neither of these can meet the detection needs. Computed Lamography (CL) technology is suitable for detecting plate-like components but lacks specialized research on trace explosives.
    Purpose
    This study aims to explore the adaptation path of dual-energy CL technology to trace explosive detection and provide a technical solution for the accurate identification of hidden explosives in electronic products.
    Methods
    A simulation model of a mobile phone containing trace TNT and an R-value measurement model were built using Geant4 to obtain dual-energy X-ray projection data. In MATLAB, the POCS-TVM algorithm was used for image reconstruction, and the ratio of attenuation coefficients (R-value) was calculated to determine the effective atomic number of substances for explosive identification.
    Results
    CL technology overcame the imaging limitations of CT for plate-like components. The R-value-based algorithm showed that the effective atomic number of TNT was 7.1388, which fell within the range of 7.1-7.4 for explosives. Additionally, the correlation coefficient of the fitted curve for low-high energy projection data reached 0.999.
    Conclusions
    This study verifies the feasibility of dual-energy CL for trace explosive detection, provides a new technical path for identifying hidden explosives in electronic products, and is of great significance for enhancing nuclear security and anti-terrorism security inspection capabilities.
  • loading
  • [1]
    孟祥承. 爆炸物及毒品的探测技术[J]. 核电子学与探测术, 2003, 23(4): 371-379,363 doi: 10.3969/j.issn.0258-0934.2003.04.023

    Meng Xiangcheng. Explosives and narcotic detection technogies[J]. Nuclear Electronics & Detection Technology, 2003, 23(4): 371-379,363 doi: 10.3969/j.issn.0258-0934.2003.04.023
    [2]
    梁永磊, 黄寅生, 钮雪冰, 等. 典型爆炸物探测技术研究现状与发展[J]. 中国安防, 2015(22): 74-78

    Liang Yonglei, Huang Yinsheng, Niu Xuebing, et al. Research status and development of typical explosive detection technologies[J]. China Security & Protection, 2015(22): 74-78
    [3]
    Sheridan H, Reingold E M. The holistic processing account of visual expertise in medical image perception: a review[J]. Frontiers in Psychology, 2017, 8: 1620. doi: 10.3389/fpsyg.2017.01620
    [4]
    刘彦韬, 李昕, 尚嘉宣, 等. 康普顿散射成像技术发展及应用[J]. 现代物理知识, 2023, 35(6): 3-11

    Liu Yantao, Li Xin, Shang Jiaxuan, et al. Development and application of Compton scattering imaging technology[J]. Modern Physics, 2023, 35(6): 3-11
    [5]
    万欣, 刘锡明, 吴志芳. 计算机分层成像技术概述[J]. CT理论与应用研究, 2014, 23(5): 883-892

    Wan Xin, Liu Ximing, Wu Zhifang. Review of Computed laminography[J]. CT Theory and Applications, 2014, 23(5): 883-892
    [6]
    O’Brien N, Boardman R, Sinclair I, et al. Recent advances in X-ray cone-beam computed laminography[J]. Journal of X-Ray Science and Technology, 2016, 24(5): 691-707. doi: 10.3233/xst-160581
    [7]
    Tian Tian, Xu Feng, Han J K, et al. Rapid diagnosis of electromigration induced failure time of Pb-free flip chip solder joints by high resolution synchrotron radiation laminography[J]. Applied Physics Letters, 2011, 99: 082114. doi: 10.1063/1.3628342
    [8]
    Verboven P, Herremans E, Helfen L, et al. Synchrotron X-ray computed laminography of the three-dimensional anatomy of tomato leaves[J]. The Plant Journal, 2015, 81(1): 169-182.
    [9]
    傅健, 张昌盛, 朱国港, 等. X射线分层层析成像技术及在航空航天领域的应用[J]. 航空制造技术, 2019, 62(14): 49-54

    Fu Jian, Zhang Changsheng, Zhu Guogang, et al. Development and application of X-ray computed laminography for aerospace[J]. Aeronautical Manufacturing Technology, 2019, 62(14): 49-54
    [10]
    Chen Yuan, Lin Na. Three-dimensional X-ray laminography and application in failure analysis for System in Package (SiP)[C]//Proceedings of 2013 14th International Conference on Electronic Packaging Technology. 2013: 746-749.
    [11]
    田忠建, 余海军, 汪粼波, 等. 正交直线扫描计算机分层成像研究[J]. 光学学报, 2020, 40: 2211002 doi: 10.3788/AOS202040.2211002

    Tian Zhongjian, Yu Haijun, Wang Linbo, et al. Orthogonal translation computed laminography[J]. Acta Optica Sinica, 2020, 40: 2211002 doi: 10.3788/AOS202040.2211002
    [12]
    曹大泉. 板状构计算机分层成像系统几何校正及性能研究[D]. 北京: 中国科学院大学, 2013

    Cao Daquan. Geometric correction and performance study of plate-structured computerized laminographic imaging system[D]. Beijing: University of Chinese Academy of Sciences, 2013
    [13]
    蔡玉芳, 李屏懿, 王珏, 等. 板壳结构物体计算机分层成像检测技术研究进展[J]. 仪器仪表学报, 2020, 41(1): 11-25

    Cai Yufang, Li Pingyi, Wang Jue, et al. Recent advances in computed laminography for nondestructive testing of plate-shell objects[J]. Chinese Journal of Scientific Instrument, 2020, 41(1): 11-25
    [14]
    Wei Zenghui, Yuan Lulu, Liu Baodong, et al. A micro-CL system and its applications[J]. Review of Scientific Instruments, 2017, 88: 115107. doi: 10.1063/1.4989444
    [15]
    Sidky E Y, Pan Xiaochuan. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization[J]. Physics in Medicine & Biology, 2008, 53(17): 4777-4807. doi: 10.1088/0031-9155/53/17/021
    [16]
    Zhang Hanming, Wang Linyuan, Li Lei, et al. Optimization-based image reconstruction in x-ray computed tomography by sparsity exploitation of local continuity and nonlocal spatial self-similarity[J]. Chinese Physics B, 2016, 25: 078701. doi: 10.1088/1674-1056/25/7/078701
    [17]
    Liu Yuhang, Liu Yi, Zhang Pengcheng, et al. Cone-beam computed tomography based on truncated adaptive-weight total variation[J]. NDT & E International, 2023, 133: 102755. doi: 10.1016/j.ndteint.2022.102755
    [18]
    Osipov S P, Udod V A, Wang Yanzhao. Identification of materials in X-ray inspections of objects by the dual-energy method[J]. Russian Journal of Nondestructive Testing, 2017, 53(8): 568-587. doi: 10.1134/S1061830917080058
    [19]
    胡紫薇, 项安, 陈奕杰. 基于双能X射线的液体危险品识别分类方法[J]. 无损检测, 2020, 42(9): 63-68

    Hu Ziwei, Xiang An, Chen Yijie. Reconition of dangerous liquid based on dual energy X-ray[J]. Nondestructive Testing, 2020, 42(9): 63-68
    [20]
    Kemp M C. A review of sensor data fusion for explosives and weapons detection[C]//Proceedings of SPIE 8710, Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing XIV. 2013: 87100X.