Magnetic field measurement of HIRFL-CSR experimental ring electron cooling device

  • The cooling time and cooling efficiency in electron cooling device strongly depend on the transverse temperature of electron beam. In order to reduce this temperature, a new type of cooling section solenoid composed of 68 coils was used in the HIRFL-CSR electron cooling device to produce a high parallelism magnetic field. With the Hall probe, the components of the magnetic field along the ion beam orbit were measured, and using the compass method the magnetic field parallelism in cooling section was measured. According to the measured results, the magnetic axis angle of each coil with respect to the geometric axis was regulated correspondingly. The magnetic field nonparallelism in the cooling section less than 1×10-4 was achieved and a magnetic induction strength of 0.078 T was obtained.