Theoretical and numerical analysis of auxiliary heating for cryogenic target fabrication
-
Abstract
In order to compensate for the nonsphericalsymmetric heat flux in the hohlraum, auxiliary heating is usually applied to the outside wall of the hohlraum during the cooling process. A one-dimensional heat exchange theoretical model has been proposed in the indirect-drive target, to analyze the required auxiliary heat flux. With a two dimensional axi-symmetric model, the auxiliary heating mechanism has been simulated by FLUENT code. The optimum heat flux which is 635 W/m2 has been obtained as the heaters around the outside of the hohlraum about 1.3 mm above and below the mid-plane. The result is in good agreement with the theoretical model.
-
-