Electrical insulation design and numerical simulation analysis of 1 MV compact repetitive Marx generator
-
Abstract
An electrical insulation optimum design and electric-field numerical simulation of a 1MV compact repetitive Marx generator filled with sulfur hexafluoride gas was performed. Two critical insulating regions in Marx generator, modular switch cavity and outer shell were well-designed with compact dimension base on the analysis of sulfur hexafluoride insulating property in static and pulse high-voltage environment, 3D electric-field numerical simulation results of the interested regions indicate that the current design meets the insulating requests of Sulfur hexafluoride at 0.3 MPa.
-
-