zhao hui, liu kun, cai tingdong, et al. Simultaneous trace detection of carbon monoxide and methane at 2.33 μmJ. High Power Laser and Partical Beams, 2011, 23(09).
Citation: zhao hui, liu kun, cai tingdong, et al. Simultaneous trace detection of carbon monoxide and methane at 2.33 μmJ. High Power Laser and Partical Beams, 2011, 23(09).

Simultaneous trace detection of carbon monoxide and methane at 2.33 μm

  • The spectrum of a series of low concentration carbon monoxide and mixed gas (carbon monoxide, methane and nitrogen) was obtained around 2.33 μm using a tunable distributed feedback semiconductor laser with an astigmatic mirror multi-pass absorption cell (optical path length 100 m) at room temperature through direct absorption technique. The absorption lines of carbon monoxide at 4 288.289 8 cm-1 and methane at 4 287.650 15 cm-1 were chosen for trace detection. At the total pressure of 40 698 Pa, the detection limits of carbon monoxide and methane were gotten respectively, i.e. 8.15×10-6 for carbon monoxide (signal-to-noise ratio is about 216) and 18.48×10-6 for methane (signal-to-noise ratio is about 147).