yang yongliang, wang junhua, liu zuping, et al. Update and experiment results of Hefei light source transverse feedback systemJ. High Power Laser and Partical Beams, 2010, 22(01).
Citation: yang yongliang, wang junhua, liu zuping, et al. Update and experiment results of Hefei light source transverse feedback systemJ. High Power Laser and Partical Beams, 2010, 22(01).

Update and experiment results of Hefei light source transverse feedback system

  • The transverse analog feedback system of Hefei light source has been redeveloped. The new improved designs including beam position signal processing unit, DC-component signal removing unit, vector signal computing unit, etc, are described and new system’s commissioning results are discussed. The transverse coupled bunch instability at 200 MeV injection status is experimentally studied. The results show that, the injection damping rate is improved from 1.22 ms to 0.16 ms and the remnant beta oscillation can be suppressed.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return