ma chenggang, xie min, liu yuntao, et al. Design and experimental research on 1.2 MV pulse transformerJ. High Power Laser and Partical Beams, 2010, 22(03).
Citation: ma chenggang, xie min, liu yuntao, et al. Design and experimental research on 1.2 MV pulse transformerJ. High Power Laser and Partical Beams, 2010, 22(03).

Design and experimental research on 1.2 MV pulse transformer

  • This paper summarized the design method of a 1.2 MV pulse transformer, which adopted the helix-involute winding to enlarge the isolation distance between the winding and the magnetic core. The numerical simulation of ANSYS showed that the maximum electric field was less than 18 kV/mm in this transformer. The local-discharge phenomena of the winding to the insulator were solved through experimental research. The derived pulse transformer could meet the following design specifications:1.2 MV output voltage, 100 Hz repetition frequency and 1 min single runtime.
  • loading