liu jianbo, li hong, chen nan, et al. Alignment for large-scale accelerator after ground vibrationJ. High Power Laser and Partical Beams, 2010, 22(04).
Citation: liu jianbo, li hong, chen nan, et al. Alignment for large-scale accelerator after ground vibrationJ. High Power Laser and Partical Beams, 2010, 22(04).

Alignment for large-scale accelerator after ground vibration

  • Take the Dragon-Ⅰ accelerator as an example, the structure response under strong vibration has been calculated using time history analysis method for the large scale accelerator, and the offsets of key points on the accelerator were measured. Numerical results show that there is 2 mm deformation in the middle of the accelerator, and in this segment the measured alignment offset is about 0.6 mm, and the measured displacement is about 2 mm. Based on the analysis of numerical calculation and measurement, the linear deviation of mechanical axis is less than ±0.2 mm after alignment. The analysis show that the calculation results can provide references for measuring point arrangement, on-site inspection and measurement data analysis.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return