gu liming, sun baogen, shen chaobo, et al. Photon beam position measurement system based on four-quadrant detectorJ. High Power Laser and Partical Beams, 2010, 22(12).
Citation: gu liming, sun baogen, shen chaobo, et al. Photon beam position measurement system based on four-quadrant detectorJ. High Power Laser and Partical Beams, 2010, 22(12).

Photon beam position measurement system based on four-quadrant detector

  • In order to overcome the limitation that the two-wire monitor cannot measure the beam position in vertical and horizontal directions at the same time, a new photon beam position measurement system based on four-quadrant detector has been developed at the Hefei Light Source(HLS), and the logarithmic ratio method is used for data processing. After the calibration of the optical imaging system and the four-quadrant detector, main parameters of the photon beam position measurement system were obtained. In horizontal direction, the linear range is ±1.83 mm, and the sensitivity is 0.471 2 mm-1. In vertical direction, the linear range is ±1.32 mm, and the sensitivity is 0.635 0 mm-1. The system has a good performance price ratio.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return