?Fault analysis of chemical oxygen iodine laser based on fault tree
-
Abstract
The paper establishes a fault tree model for chemical oxygen iodine laser(COIL) considering power abnormity as its peak affair of fault, and then makes down-way qualitative analysis and quantitative analysis with the minimum cut-set theory. It is indicated that the reliability of iodine supply subsystem is minimum, followed by the chlorine supply subsystem, in the seven subsystems of COIL. The probability at which the power of COIL is abnormal is 3.99%, that is, the reliability of laser is 96.01%.
-
-