shang lei, wang xiang-qi, jiang dao-man, et al. Coating technology improvement of ceramic chamber and measurement of time characteristic of pulsed magnetic fieldJ. High Power Laser and Partical Beams, 2004, 16(03).
Citation: shang lei, wang xiang-qi, jiang dao-man, et al. Coating technology improvement of ceramic chamber and measurement of time characteristic of pulsed magnetic fieldJ. High Power Laser and Partical Beams, 2004, 16(03).

Coating technology improvement of ceramic chamber and measurement of time characteristic of pulsed magnetic field

  • Improvement status of HLS ceramic chambers was presented. A new method of inner surface coating of ceramic chambers with Mo-metallization was developed. The rise time characteristic of the pulsed magnetic field was greatly improved. Injection rate of the storage ring increased after installation of the new chamber. A two-coil method of measuring magnetic field was established. The resolution of rise time reaches nano-second range and the waveforms of measurement were presented.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return