LTD单路验证装置电流测量

Current measurement for LTD single branch verification device

  • 摘要: 为测量LTD单路验证装置的过渡段与出口电流,设计和标定了B-dot电流探头。采用径向传输线对电流探头进行了线下标定,并开展相应验证实验证实了标定的有效性。实验表明:探头安装深度和角度误差导致的探头灵敏度偏差约为1%; 当阴阳极间距大于探头孔直径时,B-dot标定结果基本不受阴阳极间距的影响;对于本装置涉及的直径较大的同轴线,用径向线模拟标定结果是有效的。从LTD单路验证装置的实验结果可知,4个过渡段至出口的阳极电流有轻微的损失,而阴极电流逐步减小。

     

    Abstract: To measure the transition section and outlet current of LTD single branch verification device, a B-dot current probe is designed and calibrated. The radial transmission line is used to calibrate the current probe offline, and the corresponding verification experiments are carried out to verify the effectiveness of the calibration. The experimental results show that the sensitivity deviation of the probe is about 1% due to the errors of probe installation depth and angle. When the distance between the cathode and the anode is greater than the diameter of the probe hole, the B-dot calibration result is independent of the distance. For the coaxial transmission line with large diameter involved in the device, the simulation and calibration results of radial transmission line are effective. According to the experimental results of the LTD single channel verification device, the difference of anode current from the four transition sections to the outlet is very small, while the cathode current decreases gradually.

     

/

返回文章