脉冲晶闸管微观接触界面电热特性表征模型与验证

Electrothermal characterization model for the micro-contact interface of pulse thyristors

  • 摘要: 脉冲晶闸管工作在强流脉冲工况,重复的电磁热力联合冲击会导致局部过温造成铝层电熔蚀、进而加速晶闸管热疲劳失效。针对由于接触界面电热效应产生的失效问题,综合考虑表面粗糙度、外施压力、电极图案和载流子扩散等因素,建立了脉冲晶闸管微观接触界面电热特性表征模型,并在脉冲工况下进行了仿真模拟。设计了晶闸管电熔蚀加速老化试验验证仿真的正确性,在重复放电140次时,开关阳极表面外圈出现明显铝层熔蚀现象;当放电次数达到400次时,硅坑在更靠近门极位置出现。试验结果证明了模型对电熔蚀失效规律的预测精度,为脉冲晶闸管电熔蚀失效的定量评估提供了可靠技术支撑。

     

    Abstract:
    Background Pulse thyristors operate under high-current pulse conditions, where repeated combined electromagnetic and thermal stresses cause localised overheating. This leads to electrothermal erosion of the aluminum layer, accelerating thermal fatigue failure of the thyristor.
    Purpose This study aims to establish an electrothermal characterization model to evaluate the electro-erosion effect, thereby providing reliable technical support for the quantitative assessment of pulse thyristor electrical erosion failures.
    Methods A micro-scale contact interface electrothermal characteristic characterization model for pulse thyristors was established. This model comprehensively considers factors such as surface roughness, applied pressure, electrode patterns, and carrier diffusion, and was simulated under pulsed operating conditions. Furthermore, an accelerated aging test for thyristor electro-erosion was designed to validate the simulation's accuracy.
    Results Experimental observations revealed that after 140 repeated discharges, significant aluminum layer erosion appeared on the outer ring of the switch anode surface. When the discharge cycles reached 400, silicon pits emerged closer to the gate position.
    Conclusions The experimental results successfully validated the model's predictive accuracy regarding the failure mechanisms of electrical erosion. This proposed model provides reliable technical support for the quantitative assessment of pulse thyristor electrical erosion failures.

     

/

返回文章
返回