Abstract:
Background The ion-induced secondary electron yield (SEY) is a key parameter in describing electron emission during ion–solid surface interactions and affects surface charge balance, plasma sheath potential, beam transport, and detector response. However, accurate SEY measurement for keV metal ions remains challenging because the space-charge field of the ion beam deflects low-energy secondary electrons and prevents their complete collection.
Purpose This study presents a reliable method for measuring the SEY of metal ions incident on engineering alloys and metal targets and clarifies the dependence of SEY on ion energy, ion species, and incidence angle.
Methods A measurement system based on a cylindrical collector with adjustable bias was designed and constructed. A stepwise bias strategy was adopted: a negative bias of −500 V was applied to the collector to suppress secondary electrons and determine the incident ion current, whereas a positive bias, selected by a quasi-static two-dimensional electrostatic model, was applied to collect the emitted electrons completely. The SEY was obtained by decoupling the contributions of the two currents.
Results Measurements were performed for Ti and Gd ions at energies of 8–20 keV incident on 316L stainless steel, GH3625, Monel 400, Ta, and Mo targets at incidence angles of 0°–40°. The measured yields agree well with predictions from a semi-empirical model based on the ionization energy deposition and the escape probabilities of secondary electrons. The SEY increases monotonically with ion energy. At an incidence angle of 40°, the yield is higher than that at normal incidence. At the same incident energy, Gd ions produce substantially higher yields than Ti ions.
Conclusions The proposed stepwise bias method provides reliable SEY data for keV metal ions and engineering targets. The observed dependences are attributed mainly to near-surface ionization energy deposition, electron escape probability, and the geometric path effect. The results provide a useful experimental basis for beam-line design and precision measurement in ion-beam and fusion-related applications.