HT-6M托卡马克蒸钛硼化实验的可见辐射测量

MEASUREMENT OF VISIBLE RADIATION IN HT-6M TOKAMAK WITH TITANIUM GETTERING AND BORONIZATION

  • 摘要: 给出了在蒸钛和硼化实验中碳氧杂质以及中性氢的朝内通量的变化。在蒸钛实验中,碳氧杂质朝内通量减小2倍以上,中性氢的朝内通量减小40%,粒子循环系数由0.95降到0.85.在硼化实验中,碳氧杂质朝内通量减小60%左右,中性氢的朝内通量减小20%,粒子循环系数由0.95降到0.91左右.充分表明钛和硼化能有效地控制碳氧杂质的来源,改善粒子循环和杂质循环。

     

    Abstract: The behaviour of hydrogen and impurity (C and O) flux in HT-6M Tokamak with Titaium gettering and boronization is presented. Oxygen and carbon influx reduce more than two times. neutral hydrogen influx decreases about 40% and the particle recycling coefficient reduces from 0.95 to 0.85 after Ti gettering. Oxygen influx reduces by a factor of two. carbon influx decreases about 60%, neutral hydrogen influx reduces about 20% and the particle recycling coefficient reduces from 0.95 to 0.91 after boronization. These results show that Ti gettering and boronization can effectively control the source of carbon and oxygen impurities, reduce particle recycling and improve particle confinement.

     

/